Spool Matches Pipe - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls whether the weld numbers on the spool isometric match those on the full isometric drawing. This option is not available for Smart 3D models.

Select the check box for spool weld numbers to match pipe weld numbers. If you clear the check box, spool isometric weld numbers are done separately.

Defines:

Option Switch - 53, Pos 3
I-Configure - Drawing.Welds.SpoolMatchesPipe

For spool weld numbers to match the full isometric numbers, the properties that affect the number of welds and the sequence used must be the same for both spool and full styles.