Field Fit Offshore Allowance - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Sets the amount of extra pipe that is added at loose flange and field fit weld (FFW) positions for offshore piping. Extra pipe is added both to cut pipe length dimensions and to pipe quantities on the isometric drawing.

Type 0 to obtain zero allowance, or type a value (in the range 0-999) of an alternative allowance.

Defines:

Option Switch - 22, Pos 4-6
I-Configure - CutList.OffShoreAllowance