Treat IDFGEN Floating Disconnect as Error - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls how the software reports a floating disconnection that it finds during isometric extraction.

When you select the check box, the drawing is not produced if the software encounters a Floating disconnect error (code 2023) during the extraction process. An error message is also written to the Smart 3D drawing log.

If you do not select Treat IDFGEN Floating Disconnect As Error, the software writes a message to the log file but produces the drawing as usual despite the disconnected pipeline. This is the default behavior.

Defines:

Option Switch - N/A
I-Configure - S3D.Drawing.Controls.TreatIDFGEN2023AsError

  • The software uses the standard error icon to indicate the drawing failure.

  • Error 2023 occurs when IDFGEN detects out-of-line items (such as bolts, supports, and other positional items) that are left over from the previous isometric extraction.