Disables the default behavior of the software to treat taps on pipe as set-on tees (or tee-stubs) when generating the isometric drawing or creating a PCF.

By default, the software converts all radial taps off pipe to set-on tees.

When you select this option, all taps that you place on pipe in the model also display as taps on the piping isometric drawing and in the PCF. This setting causes the following:

  1. The software dimensions the branch to the tap point, which is the surface on the pipe. Typically, the requirement is for the dimension to run to the centerline of the header.

  2. Isogen expects taps on pipes to be the exception rather than the rule. As such, large numbers of taps can prevent Isogen from positioning these taps correctly on the isometric drawing.

Defines:

Option Switch - N/A
I-Configure - S3D.Drawing.Content.DisableTapToTeeStubConversion