The following AUTO-CHANGE commands are supported:
Automatically detects blind flanges used as a reducing flange. The command then changes the flange to a reducing flange (65 record), and adds a 0 record.
AUTO-CHANGE BLIND-FLANGES
AUTO-CHANGE FLANGE-END-PREPARATIONS
Automatically detects a flange record with an associated 120 record, duplicating the end preparation of flanged. The software then removes the 120 record.
AUTO-CHANGE FLANGE-END-PREPARATIONS
Looks at the connected components and automatically changes the flat direction on reducers, reducing flanges, or both.
AUTO-CHANGE FLAT-DIRECTION ALL
AUTO-CHANGE FLAT-DIRECTION REDUCERS
AUTO-CHANGE FLAT-DIRECTION FLANGES
Detects end caps (125) used as a reducing component and adds a 0 record, if required.
AUTO-CHANGE REDUCING-CAPS
Detects a reducing flange that has equal bores. The command then changes the flange from a 65 record to a 105 record. The command also changes the SKEY from FLRC to FLSO.
AUTO-CHANGE REDUCING-FLANGES
Detects an angle relief valve (90, 93 record) with SKEY RA**. If the command detects no movement in the 90 or 93 record, the command changes the SKEY to RV**, as in RVFL.
AUTO-CHANGE RELIEF VALVES
Changes the bores on supports to that of the previous component.
AUTO-CHANGE SUPPORT-BORES