A Trunnion support uses all the General Attributes specified in the Common Attributes section and the following attributes:

Attribute Name

Description

Implementation Details

IJUAhsTrunnType::
TrunnionType

Specifies the codelist value that determines if the Trunnion is a single or a Double Trunnion.

You can use a Double Trunnion on a straight pipe only and a Single Trunnion on a straight pipe or on elbows.

1 - Single

Single Trunnion Support

2 - Double

Double Trunnion Support

IJUAhsCapConfig::
CapConfiguration

Specifies a codelist value that determines how a cap plate is connected to the end of the Trunnion Pipe.

1 - External

Trunnion - Cap Configuration - External

2 - Internal

Trunnion - Cap Configuration - Internal

IJUAhsHorzPipeConn::
HorzPipeConnection

Specifies a codelist value that determines the point at which the Trunnion connects with the supporting structure when the Trunnion is placed on a pipe.

This attribute is used only when the Trunnion is supporting a pipe or an elbow that is parallel to the supporting structure.

1 - Center

Trunnion Support - Horizontal Pipe Connection - Center

2 - Toward

Trunnion Support - Horizontal Pipe Connection - Toward

3 - Away

Trunnion Support - Horizontal Pipe Connection - Away

IJUAhsElbowConn::
ElbowConnection

Specifies a codelist value that determines the point at which the trunnion connects with the supported elbow.

This attribute is used only when the Trunnion supports a pipe elbow.

1 - Center - Trunnion is lined up with the center of the horizontal pipe.

Trunnion Support - Elbow Connection - 1 Center

2 - Inside - Top or bottom of the trunnion os lined up with the horizontal pipe on the inside of the elbow curve.

Trunnion Support - Elbow Connection - 2 Inside

Trunnion Support - Elbow Connection - 3 Outside

3 - Outside - Bottom or top of the trunnion is lined up with the horizontal pipe on the outside of the elbow curve.

Trunnion Support - Elbow Connection - 3 Outside - a

Trunnion Support - Elbow Connection - 3 Outside - b

4 - Top - Top of the trunnion is lined up with the bottom of the horizontal pipe, irrespective of the direction of the elbow curve.

Trunnion Support - Elbow Connection - 4 Top - a

Trunnion Support - Elbow Connection - 4 Top - b

5 - Bottom - Bottom of the trunnion is lined up with the bottom of the horizontal pipe, irrespective of the direction of the elbow curve.

Trunnion Support - Elbow Connection - 5 Bottom - a

Trunnion Support - Elbow Connection - 5 Bottom - b

IJUAhsElbowConnOffVal::ElbowConnectionOffVal

Specifies the offset distance from Pipe center.

trunchion1

IJUAhsElbowConnOffValRl::ElbowConnectionOffValRl

Specifies a rule to get the ‘ElbowConnectionOffVal’ value.

If you specify a value, the software gets the ‘ElbowConnectionOffVal’ using rule.