IJUAhsSupportNumber::SupportNumber - Defines the support detail number as specified in the support specification. This value is used by the default BOM function when generating the BOM Description for the support.

IJUAhsSteelStandard::SteelStandard - Defines the steel standard used by the support. If there are any external rules for the steel section, this attribute is used to determine standard to use.

IJUAhsFrameType::FrameType - Defines the type of the frame shape. This attribute is used by the rules to determine the support frame type. You can add additional code-List values as required. The accepted values from the hsFrameType codelist in the HS_S3DAssy_Codelist.xls workbook are shown below:

  • 9 - Cantilevers

  • 10 - Braced Cantilevers

IJUAhsFrameOrientation::FrameOrientation - Defines the frame support orientation with respect to the supporting object or the global coordinate system. The accepted values from the hsFrameOrientation codelist in the HS_S3DAssy_Codelist.xls workbook are shown below:

  • 1 - Direct Orientation

  • 2 -Orthogonal Orientation

  • 3 - Tangent Orientation

IJUAhsMirrorFrame::MirrorFrame - Mirrors the frame about the bounding box. The accepted codelist values are shown below:

  • 0 - False

  • 1 - True

IJUAhsIncludeInsulation::IncludeInsulation - Specifies whether the frame should adjust its size to include pipe insulation.

  • 0 - False

  • 1 - True

IJUAhsStructureConn::StructureConnection - Specifies how the hanger beam part is connected to the structure. The accepted codelist values are shown below:

  • 1 - Normal

  • 2 - Lapped

  • 3 - Lapped-Opposite

IJUAhsJointValRl::JointValidationRule - Defines an HgrSupportRule that returns a true or false. It will be used validate the part properties like plate/stiffeners. Parts/supports properties can be set without changing the SDB supports code.