Attachment Attributes - Intergraph Smart Reference Data Standard Database - Version 12.3 - Help - Hexagon PPM

SDB for SRD Hangers and Supports Help 12.3

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13
Standard Database for Smart Reference Data Version
12.3

A Pipe to Pipe support uses the following attachments:

sdb-attachment attributes (pipe to pipe)

Attribute Name

Description

Implementation Details

IJUAhs_ShearLugPart::
ShearLugPart

Specifies the Shear Lug part number or part class to use for the support.

Specify the part number. Alternatively, specify the part class.

You can only place Shear Lugs on vertical perpendicular pipes only.

IJUAhs_ShearLugPartDef::
ShearLugPartDefinition

Specifies the number of Shear Lugs to place.

0 - None

1 - Vertical pipe (perpendicular configuration)

IJUAhs_PipeAttPart1::
PipeAttPart1

IJUAhs_PipeAttPart2::
PipeAttPart2

Specifies the pipe attachment part number or part class to use for the support.

You can use any support component with a route port as a pipe attachment. Some common pipe attachments include U-Bolts and Shoes.

IJUAhs_PipeAttPart1Def::
PipeAttPart1Definition

Determines the pipes to which PipeAttPart1 is attached.

0 - None

1 - First selected pipe

2 - First two selected pipes

3 - First three selected pipes

4 - Outside pipes

IJUAhs_PipeAttPart2Def::
PipeAttPart2Definition

Determines the pipes to which PipeAttPart2 is attached.

The software attaches PipeAttPart2 to pipes after placing all PipeAttPart1 attachments. For example, if PipeAttPart1 and PipeAttPart2 are set to 2, the software attaches PipeAttPart1 to the first two selected pipes. The software attaches PipeAttPart2 to the next two selected pipes. Subsequent pipes receive no pipe attachments.

If too few pipes are selected, the software places the pipe attachment on as many pipes as possible.

0 - None

1 - First selected pipe

2 - First two selected pipes

3 - First three selected pipes

4 - All remaining pipes

The software applies PipeAttPart2 after using all PipeAttPart1 components.

IJUAhs_Insulation::
InsulationPart

Specifies the insulation part number or part class to use for the support.

Specify the part number. Alternatively, specify the part class.

IJUAhs_InsulationRl::
InsulationRule

Specifies a hgrSupportRule that returns an insulation part number.

The hanger rule must be the name of an existing rule in the catalog.

Examples:

Rule Name: PipeAttByPipeSize

Rule ProgID: HS_S3DRules.PipeAttByPipeSize

IJUAhs_InsulationDef::
InsulationDef

Currently not available.

IJUAhs_InsulationSel::
InsulationSel

Specifies the attribute that is used to select the InsulationPart.

The InsulationPart is used by default if you do not specify any value.

hsSelection:

1 - By Rule

2 - By Input

IJUAhs_Insulation2::
Insulation2Part

Specifies the second insulation part number or part class to use for the support.

Specify the part number. Alternatively, specify the part class.

IJUAhs_Insulation2Rl::
Insulation2Rule

Specifies a hgrSupportRule that returns an insulation part number.

The hanger rule must be the name of an existing rule in the catalog.

Examples:

Rule Name: PipeAttByPipeSize

Rule ProgID: HS_S3DRules.PipeAttByPipeSize

IJUAhs_Insulation2Def::
Insulation2Def

Currently not available.

IJUAhs_Insulation2Sel::
Insulation2Sel

Specifies the attribute that is used to select the Insulation2Part.

The Insulation2Part is used by default if you do not specify any value.

hsSelection:

1 - By Rule

2 - By Input