Use the following attributes to define various dimensions of the combined guide support and data driven assemblies. The software overwrites these attributes for the limit stop, repad, and guide supports.
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhs_StopShoeHeight:: |
Specifies the shoe height of the limit stop. |
|
IJUAhs_StopAngle1:: |
Specifies the ShoeAngle1 of the limit stop support. |
|
IJUAhs_StopAngle2:: |
Specifies the ShoeAngle2 of the limit stop support. |
|
IJUAhs_StopAngle3:: |
Specifies the ShoeAngle3 of the limit stop support. |
|
IJUAhs_StopConnectTo:: |
Specifies the codelist value that determines whether the limit stop connects to a pipe or a supporting steel. |
|
IJUAhs_StopSpanOver:: |
Specifies the span measurement. This attribute is valid only when the structure connection is set to 1. |
|
IJUAhs_StopStructConn:: |
Specifies the location of the limit stop and also the position from where the limit stop clearance is measured. |
|
IJUAhs_StopClearance:: |
Specifies the space between the limit stop and the edge of the supporting steel. |
|
IJUAhs_RepadAngleDim:: |
Specifies the angle dimension of the repad. |
|
IJUAhs_RepadLength:: |
Specifies the length of the repad. |
|
IJUAhsGuideGap:: |
Specifies the gap of guide to the left side of the pipe. |
|
IJUAhsGuideGap2::GuideGap2 |
Specifies the gap of guide to the right side of the pipe. |
|
IJUAhsGuideLength:: |
Specifies the length of the guide. |
|
IJUAhsGuideShoeH:: |
Specifies the shoe height of the guide. |
|
IJUAhsGuideShoeW:: |
Specifies the shoe width of the guide. |