Limit Stop Support Attributes - Intergraph Smart Reference Data Standard Database - Version 12.3 - Help - Hexagon PPM

SDB for SRD Hangers and Supports Help 12.3

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13
Standard Database for Smart Reference Data Version
12.3

The following dimensions are used by the Limit Stop sub-assembly:

Name

User Name

Category

On Property Page

Read Only

ShoeHeight

Shoe Height

Dimensions

Yes

No

Angle1

Angle 1

Dimensions

Yes

No

Angle2

Angle 2

Dimensions

Yes

No

Angle3

Angle 3

Dimensions

Yes

No

ConnectTo

Connect To

Dimensions

Yes

No

SpanOver

Span Over

Dimensions

Yes

No

StructureConnection

Structure Connection

Dimensions

Yes

No

StopClearance

Stop Clearance

Dimensions

Yes

No

Attribute Name

Description

Implementation Details

IJUAhsShoeHeight::
ShoeHeight

Specifies the shoe height of the limit stop.

IJUAhsAngle1::Angle1

Specifies the ShoeAngle1 of the limit stop support.

IJUAhsAngle2::Angle2

Specifies the ShoeAngle2 of the limit stop support.

IJUAhsAngle3::Angle3

Specifies the ShoeAngle3 of the limit stop support.

IJUAhsConnectTo::
ConnectTo

Specifies the codelist value that determines whether the limit stop connects to a pipe or a supporting steel.

IJUAhsSpanOver::
SpanOver

Specifies the span measurement.

This attribute is valid only when the structure connection is set to 1.

IJUAhsStructureConnection::
StructureConnection

Specifies the location of the limit stop and the position from where the limit stop clearance is measured.

IJUAhsStopClearance::
StopClearance

Specifies the space between the limit stop and the edge of the supporting steel.

For more details on these attributes, refer Limit Stop.