Authentication level must be set to NONE - SmartPlant Foundation - IM Update 46 - Help - Hexagon

SmartPlant Foundation Help

Language
English
Product
SmartPlant Foundation
Search by Category
Help
SmartPlant Foundation / SDx Version
10
SmartPlant Markup Plus Version
10.0 (2019)
Smart Review Version
2020 (15.0)

Error Message

Authentication Level needs to be set to NONE.

Solution

The following configuration is required on all SmartPlant Foundation servers that run the SmartConverter.

  1. Click Start > Administrative Tools > Component Services.

  2. In the tree view, expand Component Services > Computers > My Computer > DCOM Config.

  3. Right-click SmartSketch Symbol.

  4. On the shortcut menu, click Properties.

  5. Click the General tab.

  6. Change the Authentication Level option to None.

  7. Click the Identity tab.

  8. Click This user, and type the server name and user name separated by \ in the User box.

    The user must have permission to run SmartSketch on the SmartPlant Foundation Server.

  9. In the Password and Confirm password boxes, type the password for the SmartSketch Symbol identity user account.

  10. Give the SPFUsers group permission to launch SmartSketch by performing the following steps:

    • Click the Security tab.

    • Change the Launch and Activation Permissions to Customize.

    • Click Edit in the Launch and Activation Permissions section, and add the SPFUsers group created by the SmartPlant Foundation Server Manager.

      SmartSketchSymbolProperties

      LaunchPermission

  11. Click OK to dismiss the Launch Permission dialog box, and then OK again to dismiss the SmartSketch Symbol Properties utility.