Scenario 2: Loops - Intergraph Smart P&ID - Help - Intergraph

SmartPlant P&ID Drawing Manager Help

Language
English
Product
Intergraph Smart P&ID
Search by Category
Help
SmartPlant Foundation / SDx Version
Smart P&ID Version
7.1 (2014 R1)
Smart Engineering Manager Version
7.2 (2014 R2)
Smart P&ID Web API Version
(none)

The following workflow demonstrates using shared items in a connected Workshare collaboration using projects.

1

The Plant creates Drawing A and places 3 DCS instruments.

2

Project 1 checks out Drawing A and creates the following loops:

P-100 in the drawing stockpile

P-101 in plant stockpile (shared = False)

P-102 in plant stockpile (shared = True)

Project 1 verifies via the EDE that there are 3 DCS instruments and 3 loops in the drawing.

3

Project 1 closes Drawing A.

Drawing A becomes Drawing A'.

4

Project 2 fetches (with read/write permissions) Drawing A' from Project 1.

Project 2 opens Drawing A' and verifies via the EDE that P-100 is in the drawing stockpile and that there are 3 DCS instruments, then closes Drawing A'.

Project 2 assigns ownership of Drawing A' to Satellite 2.1 and synchronizes shared items.

5

Satellite 2.1 executes Get Latest Version from Remote command and synchronizes shared items.

Satellite 2.1 opens Drawing A' and verifies via the EDE that P-100 is in the drawing stockpile and that there are 3 DCS instruments, then closes Drawing A'.

6

Project 1 assigns ownership of Drawing A' to Satellite 1.1 and synchronizes shared items.

Satellite 1.1 executes Get Latest Version from Remote command and synchronizes shared items.

Satellite 1.1 opens Drawing A' and verifies via the EDE that P-100 is in the drawing stockpile and that there are 3 DCS instruments, then closes Drawing A'.

7

Satellite 1.1 creates Drawing B and places an instrument. Drawing B becomes Drawing B'.

8

Satellite 1.1 opens Drawing B', verifies via the EDE that only the P102 loop tag is available for assignment (confirming that synchronizing shared items brought the loop over to the satellite), then closes Drawing B'.

9

Satellite 2.1 creates Drawing C and places an instrument. Drawing C becomes Drawing C'.

10

Satellite 2.1 opens Drawing C', verifies via the EDE that only the P102 loop tag is available for assignment (confirming that synchronizing shared items brought the loop over to the satellite), then closes Drawing C'.

11

Satellite 1.1 assigns ownership of Drawing A' to Project 1 and synchronizes shared items.

12

Project 1 executes Get Latest Version from Remote command and synchronizes shared items.

Project 1 opens Drawing A' and verifies the following via the EDE:

P-100 in the drawing stockpile

P-101 in plant stockpile (shared = False)

P-102 in plant stockpile (shared = True)

3 DCS instruments

Project 1 closes Drawing A' and then checks Drawing A' into the Plant.

13

The Plant opens Drawing A' as read-only and verifies via the EDE that P-100 is in the drawing stockpile and that there are 3 DCS instruments.

See Also

Projects vs. Workshare