Part Attributes (L-Frame) - Intergraph Smart Reference Data Standard Database - Version 12.4 - Help - Hexagon

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13.1
Standard Database for Smart Reference Data Version
12.4

A L-Frame uses the following part attributes:

Attribute Name

Description

Implementation Details

IJUAhsLeg1::

Leg1Part

The Part-Number or Part Class of the first support leg to use for the support.

Option 1 – Specify a Part-Number or Part Class directly

Option 2 – Use a HgrRule to get the Part

The box frame is a mandatory part. Either a Leg1Part or Le1Rule must be specified.

IJUAhsLeg1Rl::

Leg1Rule

An HgrSupportRule that returns a hanger beam pipe Part-Number. The Hanger Rule should be present in the catalog; it can be the name of a rule, or a rule ProgID.

IJUAhsLeg1Ang::

Leg1OrientationAngle

Specifies the angle of rotation about the axis of the leg for the first member of the support.

hsSteelOrientalAngle:

image273

IJUAhsLeg1BeginOH::

Leg1BeginOverhangValue

Specifies a numerical value for the distance that the first leg should overhang past the main member. To select the overhang value using Leg1BeginOverhangRule, do not type any value for this property.

image240

IJUAhsLeg1BeginOHRl::

Leg1BeginOverhangRule

Defines an HgrSupportRule that returns the distance that the first leg should overhang past the main member. The hanger rule should exist in the catalog; it can be a rule name or a ProgID. The rule must return the value in the DB Units (meters). To select the overhang value directly using Leg1BeginOverhangValue, do not type any value for this property.

IJUAhsLeg1BeginOHDef::

Leg1BeginOverhangDefinition

Defines how the begin overhang should be measured.

image317

IJUAhsLeg1BeginOHSel::

Leg1BeginOverhangSelection

Uses the hsSelection codelist in the HS_S3DAssy_Codelist.xls workbook to select Leg1BeginOverhang by either input or rule.

Allowed values are:

By Rule - 1 - Leg1BeginOverhangRule is used

By Input - 2 - Leg1BeginOverhangValue is used

IJUAhsLeg1EndOH::

Leg1EndOverhangValue

Specifies the distance that the first leg should overhang past the supporting object. To select the value of the overhang using Leg1EndOverhangRule, do not type any value for this property.

image191

IJUAhsLeg1EndOHRl::

Leg1EndOverhangRule

Defines an HgrSupportRule that returns the distance that the first leg should overhang past the supporting object. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To select the value of the overhang directly using Leg1EndOverhangValue, do not type any value for this property.

IJUAhsLeg1EndOHDef::

Leg1EndOverhangDefinition

Defines how the end overhang should be measured with respect to the supporting object. If you do not type any value, a default value of 1 is used.

The following values are allowed:

image319

IJUAhsLeg1EndOHSel::

Leg1EndOverhangSelection

Uses the hsSelection Codelist in the HS_S3DAssy_Codelist.xls workbook to select Leg1EndOverhang by either input or rule.

Allowed values are:

By Rule - 1 - Leg1EndOverhangRule is used

By Input - 2 - Leg1EndOverhangValue is used

IJUAhsCapPlate1::

CapPlate1Part

Specifies the part number or the part class for the plate placed at the end of the main section and at the end connected to the member.

To select the part using CapPlate1Rule, do not type any value for this property.

Option 1 – Specify a Part-Number or Part Class directly

Option 2 – Use a HgrRule to get the Part

The cap plate is an optional part. Leave these attributes blank if you do not want to include a cap plate.

IJUAhsCapPlate1Rl::

CapPlate1Rule

Specifies the hgrSupportRule that returns the part number for the hanger beam pipe. The hanger rule must be the name of an existing rule in the catalog.

IJUAhsCapPlate1Ang::

CapPlate1Angle

Specifies the angle that CapPlate1 should be rotated about the Z-axis of the port to which the plate is attached.

IJUAhsMember1::

Member1Part

Specifies the part number or the part class of the first support member to use for the support.

Option 1 - Specify a part number or part class directly.

Option 2 - Use HgrRule to get the part.

The base support is a mandatory part. Specify either a Member1Part or Member1Rule.

IJUAhsMember1Rl::

Member1Rule

Specifies the hgrSupportRule that returns the part number for the hanger beam pipe. The hanger rule must be the name of an existing rule in the catalog.

IJUAhsMember1Ang::

Member1OrientationAngle

Specifies the angle of rotation about the axis of the leg for the first member of the support.

hsSteelOrientalAngle:

image273

IJUAhsCapPlate2::

CapPlate2Part

Specifies the part number or the part class for the plate placed at the end of the main section and at the end connected to the member.

Option 1 - Specify a part number or part class directly.

Option 2 - Use HgrRule to get the part.

The base support is a mandatory part. Specify either a Member1Part or Member1Rule.

IJUAhsCapPlate2Rl::

CapPlate2Rule

Specifies the hgrSupportRule that returns the part number for the hanger beam pipe. The hanger rule must be the name of an existing rule in the catalog.

IJUAhsCapPlate2Ang::

CapPlate2Angle

Specifies the angle that CapPlate2 should be rotated about the Z-axis of the port to which the plate is attached.

IJUAhsCapPlate3::

CapPlate3Part

Specifies the part number or the part class of the plate placed at the end of the main section and at the end connected to the first leg.

Option 1 - Specify a part number or part class directly.

Option 2 - Use HgrRule to get the part.

The base support is a mandatory part. Specify either a Member1Part or Member1Rule.

IJUAhsCapPlate3Rl::

CapPlate3Rule

Specifies the hgrSupportRule that returns the part number for the hanger beam pipe. The hanger rule must be the name of an existing rule in the catalog.

IJUAhsCapPlate3Ang:: CapPlate3Angle

Specifies the angle that CapPlate3 should be rotated about the Z-axis of the port to which the plate is attached (either BeginFace or EndFace).

For more information on how to use part specification attributes, see Part Specifications of Common Attributes section.