LV Frame support uses all the General Attributes specified in Common Attributes section and the following additional general attributes:

Attribute Name

Description

Implementation Details

IJUAhsSupportNumber::SupportNumber

The support detail number as specified on the support specification. This value will be used by the default BOM function when generating the BOM Description for the support.

IE: LVF-001

IJUAhsSteelStandard::SteelStandard

A code list value that defines the steel standard used by the support. If external rules were written to select the steel standard, this attribute would be used to determine the standard to use.

hsSteelStandard:

5 – Euro

10 – AISC

15 – CISC and so on.

IJUAhsFrameType::FrameType

A code list value that defines the type of the frame shape.

hsFrameType:

1 - U Frame

2 - L Frame

3 - T Frame

4 - Split T Shaped Frame

5 - I Shaped Frame

6 - Vertical L Frame

7 - Box Shaped Frame

8 - Braced Box Shaped Frame

9 - Cantilever

10 - Braced Cantilever

IJUAhsFrameConfiguration::FrameConfiguration

Defines the initial frame configuration on placement. This property is applicable only to U, L and LV-Frames types. You can change the configuration after placing the support by clicking Change Support Configuration on the ribbon.

Accepted values are:

1 - Frame support placed on the far side of the pipe.

image178

2 - Frame support placed on the closest side of the pipe.

image179

IJUAhsFrameOrientation:: FrameOrientation

A code list value that defines the frame support orientation with respect to the supporting object or the global coordinate system.

hsFrameOrientation:

1 - Direct towards the supporting object

image171image172

2 - Orthogonal to the global coordinate system

image173image174

3 - Tangent to the first and last selected pipes

image175image176

IJUAhsMirrorFrame:: MirrorFrame

Mirrors the frame support about the bounding box.

0 - False

image178

1 - True

image181

IJUAhsIncludeInsulation:: IncludeInsulation

Specifies whether the frame should adjust its size to include pipe insulation.

0 - False

image182

1 - True

image183

IJUAhsStructureConn:: StructureConnection

A code list value that specifies how the hanger beam part is connected to the structure.

1 - Normal

2 - Lapped

3 - Lapped-Opposite

IJUAhsSuppPosOffset::SupPosOff

Specifies the support distance from origin of the support. To determine the support position offset using SupPosOffRl, do not type any value for this property.

image218

IJUAhsSuppPosOffsetRl::SupPosOffRl

Defines a HgrSupportRule that returns the support position offset. The hanger rule name or the ProgID must exist in the catalog. To determine the support position using SupPosOff, do not type any value for this property.