Indicates where the nozzle reinforcement is located. This entry is used to interpolate among the charts in API-650 Appendix P. If reinforcing on the shell is indicated, Appendix P makes the following assumptions:

  • The reinforcing pad thickness is equal to the shell thickness.

  • The pad diameter is twice the nozzle diameter.

These assumptions are implicit in the curves presented in Appendix P and are automatically considered by the software.