Implemented API-650 11th Edition Addendum 3 changes.
This extensive Addendum changed many formulas. These formula changes will cause the answers to be different from those computed in previous versions (in many but not all cases).
-
Added user defined wind pressure vs. Elevation Input.
-
Added calculations for Anchor chairs per AISI.
-
The user interface has been through a minor update.
-
The output processor has been updated.