Enter the estimated rate of change of the pit characteristic depth. Pits can corrode in many forms and sometimes the pit depth is not affected by corrosion. If you leave this value at 0, the software does not use a pit depth corrosion rate in the remaining life pitting calculations. However, if corrosion affects both the pit diameter and the depth and you specify those values, the software takes both propagation rates into consideration for the remaining life calculation.