Use the structure translation mapping sheets in the PDMSS3DImportMapping.xls workbook to map PDMS structure attributes to the correct Smart 3D structure properties. Before importing PDMS structure model data to Smart 3D, modify these sheets to ensure that the following criteria are met:
-
All cross-sections and PLine attributes in the PDMS catalog are mapped to the corresponding cross-sections and cardinal points in the Smart 3D model. This is mandatory for the import of members to Smart 3D.
After you complete all of the mapping in the PDMSS3DImportMapping.xls workbook, run PDMS Import Validation to validate the mapping data in the workbook. Resolve any missing entries reported by the validation tool. For more information, see PDMS Import Validation Command.
You can define the Default value in each sheet as the PDMS PLine attribute, mapped to the Smart 3D cardinal point. The software uses the Default value only if JUSL is not defined for the section or is not mapped in the mapping file. If you do not map the Default value to a cardinal point, the software defines the cardinal point as 5-Center.
The PDMSS3DImportMapping.xls workbook delivers the following structure translation maps:
BUBoxFM_PLine
Provides mapping between the PDMS BUBoxFM cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see BUBoxFM_PLine.
BUC_PLine
Provides mapping between the PDMS BUC cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see BUC_PLine.
BUCone_PLine
Provides mapping between the PDMS BUCone cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see BUCone_PLine.
BUI_PLine
Provides mapping between the PDMS BUI cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see BUI_PLine .
BuiltUpCrossSecAdditionalAtt
Provides mapping between PDMS cross-sections with design parameters and Smart 3D standard cross-sections. Smart 3D ReferenceStandard and CrossSection attribute values are obtained from corresponding cross sections in Smart 3D catalog. For more information, see BuiltUpCrossSecAdditionalAtt .
BuiltupDesignParametersMap
Provides additional attributes, such as dimensional data, that Smart 3D sets on interfaces. Dimensional data is obtained from the corresponding cross-section design parameters in the PDMS DATAL file. For more information, see BuiltupDesignParametersMap .
BUL_PLine
Provides mapping between the PDMS BUL cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see BUL_PLine.
BUTee_PLine
Provides mapping between PDMS BUTee cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see BUTee_PLine.
BUTube_PLine
Provides mapping between the PDMS BUTube cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see BUTube_PLine .
C_PLine
Provides mapping between the PDMS C cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see C_PLine.
CoordinateSysAttrMap
Maps PDMS DATUM attributes to Smart 3D SPGCoordinateSystem class properties. For more information, see CoordinateSysAttrMap .
FootingRefMap
Provides mapping between the PDMS footing reference SPRE and the Smart 3D footing part number. For more information, see FootingRefMap .
HSSC_PLine
Provides mapping between the PDMS HSSC cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see HSSC_PLine .
HP_PLine
Provides mapping between the PDMS HP cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see HP_PLine.
HSSR_PLine
Provides mapping between the PDMS HSSR cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see HSSR_PLine .
InsulationAttrMap
Maps PDMS Insulation attributes to Smart 3D CStructInsulation class properties. For more information, see InsulationAttrMap .
InsulationMap
Provides mapping for the PDMS fire-proofing reference SPRE to the corresponding Smart 3D InsulationSpec and Length. The PDMS fire-proofing reference SPRE contains concatenated PDMS values ([SPRE]-[MATR]-[GRADE]-[FIRE]). For more information, see InsulationMap .
JointRefMap
Provides mapping between the PDMS joint reference SPRE and the Smart 3D assembly connection part number. For more information, see JointRefMap .
L_PLine
Provides mapping between the PDMS L cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see L_PLine .
M_PLine
Provides mapping between the PDMS M cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see M_PLine .
MC_PLine
Provides mapping between the PDMS MC cross-sections PLine attribute and Smart 3D standard cross-sections cardinal point. For more information, see MC_PLine.
MT_PLine
Provides mapping between the PDMS MT cross-sections PLine attribute and Smart 3D standard cross-sections cardinal point. For more information, see MT_PLine .
PIPE_PLine
Provides mapping between the PDMS PIPE cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see PIPE_PLine.
PlatePartMap
Provides mapping between PDMS FLOOR attributes and Smart 3D slab properties. For more information, see PlatePartMap.
PlateThicknessDirMap
Provides mapping between the PDMS Panel Justification attribute and the Smart 3D General Plate Thickness Direction attribute. For more information, see PlateThicknessDirMap.
RS_PLine
Provides mapping between the PDMS RS cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see RS_PLine.
S_PLine
Provides mapping between the PDMS S cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see S_PLine.
ST_PLine
Provides mapping between the PDMS ST cross-sections PLine attribute and the Smart 3D standard cross-sections cardinal point. For more information, see ST_PLine.
SlabFacePositionMap
Provides mapping between the PDMS Floor Justification attribute and the Smart 3D Slab Face Position attribute. For more information, see SlabFacePositionMap.
SPSMemberSystemCurveMap
Maps PDMS GENSEC attributes to Smart 3D SPSMemberSystemCurve (Curved Member Systems) class properties. For more information, see SPSMemberSystemCurveMap .
SPSMemberSystemLinearMap
Maps PDMS SCTN attributes to Smart 3D SPSMemberSystemLinear (Linear Member Systems) class properties. For more information, see SPSMemberSystemLinearMap.
SPSSlabEntityGWallMap
Provides mapping between PDMS GWALL attributes and Smart 3D slab properties. For more information, see SPSSlabEntityGWallMap.
SPSSlabEntityMap
Provides mapping between PDMS PANEL attributes and Smart 3D plate properties. For more information, see SPSSlabEntityMap.
SPSWallSystemSTWallMap
Provides mapping between PDMS STWALL attributes and Smart 3D straight wall properties. For more information, see SPSWallSystemSTWallMap.
SPSWallSystemWallMap
Provides mapping between PDMS WALL attributes and Smart 3D curved wall properties. For more information, see SPSWallSystemWallMap.
StandardCrossSecAdditionalAtt
Provides mapping between PDMS cross-sections and Smart 3D standard cross-sections. Smart 3D ReferenceStandard and CrossSection attribute values are obtained from the corresponding cross-sections in the Smart 3D catalog. For more information, see StandardCrossSecAdditionalAtt .
StructureClassMap
Maps the supported structure classes between PDMS and Smart 3D. This is the main mapping sheet for the structure discipline. This sheet contains cross-references to the class mapping sheets for SPSSlabEntity, Plate, SPSMemberSystemLinear, SPSMemberSystemCurve, CStructInsulation, SPGCoordinateSystem, and StructureGlobals. This mapping sheet also contains a global sheet that provides additional mapping information. For more information, see StructureClassMap.
StructureGlobalsMap
Defines global settings for structural model data import. For more information, see StructureGlobalsMap .
StructureMatSpecMap
Provides mapping for Smart 3D MaterialType and MaterialGrade attributes. This translation sets these attributes to the corresponding PDMS structural Material value. The PDMS structural Material value contains the concatenated values for Material and Grade ([MATR]-[GRADE]), which are obtained from the PDMS .datal file. For more information, see StructureMatSpecMap .
StructurePlateMatSpecMap
Provides mapping for Smart 3D PlateType and PlateGrade attributes. These attributes are set to the corresponding PDMS Panel Material value. The PDMS Panel Material value contains the concatenated values for Material and Grade ([MATR]-[GRADE]), which are obtained from the PDMS .datal file. For more information, see StructurePlateMatSpecMap .
StructureSlabMatSpecMap
Provides mapping for Smart 3D SlabType and SlabComposition attributes. These attributes are set to the corresponding PDMS Floor Material value. The PDMS Floor Material value contains the concatenated values for Material and Grade ([MATR]-[GRADE]), which are obtained from the PDMS .datal file. For more information, see StructureSlabMatSpecMap .
W_PLine
Provides mapping between the PDMS W cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see W_PLine.
WallCardinalPointMap
Provides mapping between the PDMS wall JUSL attribute and the Smart 3D wall cardinal point. For more information, see WallCardinalPointMap.
WallCrossSecCompositionMap
Provides mapping for Smart 3D wall composition, cross-section, thickness, and height attributes. These attributes are applied to the corresponding wall. The PDMS value contains the concatenated values for spec reference and material reference ([SPRE]-[MATR]), which are obtained from the PDMS .datal file. For more information, see WallCrossSecCompositionMap.
WT_PLine
Provides mapping between the PDMS WT-cross-section PLine attribute and the Smart 3D standard cross-section cardinal point. For more information, see WT_PLine.
XSectionAdditionalAttr