Sets options for adding a split to a cable tray.
Select Feature
Selects the cable tray in which you want to insert a split.
Position
Specifies the position of the split along the straight feature. This option is available if you are working in single-split mode (see Split Mode below), but it is not available if you are working in multi-split mode.
Finish
Inserts the split.
Section Length
Specifies the purchasable length of the cable tray.
If the length of the selected cable tray straight feature is less than the last-used section length, then the software sets the section length to half of the straight feature length.
Gap Width
Specifies the gap between straight sections. The maximum gap you can define is 2 inches (5 cm). The following picture shows where the gap is placed.
Reference Position
Inserts splits in the selected straight feature starting from Port 1 or Port 2 (either end of the straight feature).
Split Mode
Specifies the mode for inserting splits.
Single-Split
Inserts one split at a time.
Multi-Split
Inserts many splits along the feature. The distance between them is determined by the section length and gap width.