The source of the gasket table can be defined in the Gasket Method field on this screen. The following methods are available:
-
Spec-Header - Searches in the geometrics assigned to the pipe class on S.50.06 for the attributes DN, TEMP, and THICK from A.50.I.02. If a geometric with these attributes is found, the result is a gasket table for the corresponding pipe class. The name is the original Smart Materials geometric name. It is entered into the PMC.
-
Spec-Items - Looks for the attributes DN, (TEMP), THICK, translated on A.50.I.02, in the geometrics of the piping class. Prints out DN, (TEMP), THICK for the geometrics found. Prints the maximum temperature from M_SPEC_LIMITS after this, if the temperature was not available as a translated attribute. The naming is formed with the pattern fixed string: GS_ plus SPEC_HEADER _ID.
The sequence, default, and title of the gasket table in the PMC file can be defined here.