Click Place Fireproofing Command on the vertical toolbar.
-
Select the By Rule option to use the fireproofing properties defined in the encasement rules.
-
Select the member to which you want to apply the fireproofing.
You can select more than one member by dragging a selection fence around the members.
-
Set Condition to Add.
Set Condition to Retain if members in the selection set already have fireproofing and you do not want additional fireproofing to be placed on them.
-
In the Insulation Spec box, select the insulation specification to use.
-
Click Accept .
The software tentatively displays the fireproofing using the settings that you have specified.
-
Click Finish to place the fireproofing.