Meaning: A stair requires a side reference edge object if it is placed using a surface or plane as top support. This stair's side reference edge object is missing, likely because the side reference edge object was deleted.
Recovery:
-
Open the Structure task.
-
Click Select .
-
Set the Locate Filter to Stairs.
-
Select the stair with the error.
-
Click Select Reference Edge on the ribbon.
-
Select a new reference edge object in the model.
-
Click Finish.