Description: Labels are positioned at the end of a pipe segment when clipped by a volume
Type: COM
XML Location: [Reference Data Folder]\SharedContent\Drawings\Catalog\Labels\Templates\[Label Template Name].xml
Point Generator: Linear Object Endpoints
Geometric Analyzer: End of Segment (DrawingGAEndOfSegment)
Annotation Control Generator: Default (DefaultLabelControlGenerator)
Content Module: Default (DrawingLabelHelper)
Positioning Module: Clear Space Clipped (DwgClippedPositioning), Clear Space End of Linear Object (DwgLblEndOfSegmentPos), Clear Space Margin (DrawingMarginOnly)
Example
For more information on clipped pipes in view styles, see Clipping in Piping View Styles.
Label Template Name |
Returned Properties |
---|---|
Electrical CableTray Elevation_LineNumber_Clipped |
Name |
Electrical CableTray Plan_LineNumber_Clipped |
Name |
Electrical Cableway Plan_LineNumber_Clipped |
Name |
Electrical Equipment Elevation_LineNumber_Clipped |
Name |
Electrical Equipment Plan_LineNumber_Clipped |
Name |
HVAC Elevation_LineNumber_Clipped |
Name |
HVAC Plan_LineNumber_Clipped |
Name |
Piping Elevation_LineNumber_Clipped |
NPD, NPDUnitType, Fluid Type, Sequence Number, Spec Name |
Piping Plan_LineNumber_Clipped |
NPD, NPDUnitType, Fluid Type, Sequence Number, Spec Name |
Piping Plan_Piping Parts_RunName |
Name, PrimarySize, PriSizeNPDUnits, Insulation Purpose, PipeSpec, FluidCode |