A Shoe with Clamps support uses the following Stop attributes:
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsStopSup::StopSupport |
Specifies the part number of a Limit Stop assembly that is used in the ‘Shoe with Clamps’ support. |
The Limit Stop assembly is optional. If no secondary data driven assembly is required, leave both the StopSupport and StopSupportRule properties empty. |
IJUAhsStopSupRl::StopSupportRule |
Specifies a hanger beam rule that returns the Stop support partnumber. |
|
IJUAhsStopGap::StopGap |
Specifies the gap for the Limit Stop. |
Stop below the Shoe - The Stop gap is measured to the edge of the supporting section Stop above the supporting structure - The Stop gap is measured to the edge of the Shoe |
IJUAhsStopGapRl::StopGapRule |
Specifies a HgrSupportRule that returns the stop gap value. The hanger rule must be present in the catalog and must be a rule name. |
|
IJUAhsStopGapSel::StopGapSelection |
Overrides the codelist value that determines the origin of the selection. This property uses the hsSelection codelist. |
hsSelection: 1 - By Rule 2 - By Input |
IJUAhs_StopStructConn::StructureConnection |
Specifies whether the Limit Stop secondary support connects to the top of the supporting structure or the bottom of the Shoe. This attribute uses the hsStructConnection codelist from the DDS_Assy_Codelist workbook. |
1 = Below Shoe 2 = Above Structure |
IJUAhsActualShoeHeight::ActualShoeHeight |
Specifies the distance from pipe bottom surface to shoe bottom surface. |