In Smart Instrumentation, save the spec page as a .psr file and then open the .psr file in InfoMaker. For details, see Open a Form Page in InfoMaker.
-
To correct undershooting or overshooting on the left border, do the following:
-
Right-select the top line or on the bottom line, and on the shortcut menu select Properties.
-
On the Position tab, under X1, copy the value to the Clipboard, using a standard Microsoft shortcut (for example, CTRL+C).
-
Right-select the required horizontal line, and on the shortcut menu, select Properties.
-
On the Position tab, under X1, paste the Clipboard value, using a standard Microsoft shortcut (for example, CTRL+V).
-
-
To correct undershooting or overshooting on the right border, do the following:
-
Right-select the top line or the bottom line, and on the shortcut menu select Properties.
-
On the Position tab, under X2, copy the value to the Clipboard, using a standard Microsoft shortcut.
-
Right-select the required horizontal line, and on the shortcut menu, select Properties.
-
On the Position tab, under X2, paste the Clipboard value, using a standard Microsoft shortcut.
-
-
To correct undershooting or overshooting on the top border, do the following:
-
Right-select the left-most line or the right-most line, and on the shortcut menu select Properties.
-
On the Position tab, under Y1, copy the value to the Clipboard, using a standard Microsoft shortcut.
-
Right-select the required vertical line, and on the shortcut menu, select Properties.
-
On the Position tab, under Y1, paste the Clipboard value, using a standard Microsoft shortcut.
-
-
To correct undershooting or overshooting on the bottom border, do the following:
-
Right-select the left-most line or the right-most line, and on the shortcut menu select Properties.
-
On the Position tab, under Y2, copy the value to the Clipboard, using a standard Microsoft shortcut.
-
Right-select the required vertical line, and on the shortcut menu, select Properties.
-
On the Position tab, under Y2, paste the Clipboard value, using a standard Microsoft shortcut.
-
-
On the menu bar, select File > Save.
-
Import the page back into Smart Instrumentation.
-
Regenerate the spec page and specification, and save the specification again in Excel format.